V.9Simulation parameters

In brief

The fixed calculation parameters of the simulation, including time step, sun model, solar diameter and calculation grid, cannot be changed; the report documents them in the chapter "Simulation Parameters".

Parameter Value
Temporal resolution 1 minute, reference year without a leap day (1 January to 31 December)
Solar position NREL SPA (pvlib), apparent elevation including refraction, calculated at the mean of all PV corner points of the project (one solar position for all areas)
Solar elevations calculated above 0°
Time reference project time zone as standard time, without daylight saving time
Direct irradiance (DNI) clear-sky model according to Ineichen and Perez, climatological Linke turbidity per month, site altitude = mean terrain height of the PV corner points (one altitude per simulation)
Luminous efficacy (K) dependent on solar elevation according to Littlefair (1988), 51.8 to 96.6 lm/W
Apparent solar diameter 0.53°
Module curves reflection profile, major and minor axis per zone (up to three zones), reflection offset δ; 10° supporting points, interpolated linearly
Reference illuminance of the profiles 100,000 lx on the module surface, independent of the angle of incidence
Lobe boundary ellipse with semi-axes (lobe axis + solar diameter) / 2
Point grid (calculation points) per PV area and axis (azimuth, elevation) about 40 steps across the extent at which the area appears from the observation point; step width at most 0.125°. Finer step widths are snapped to the nearest divisor 0.125°/n, with at least 30 steps per axis; the cap of 20,000 points per area takes precedence. Points at the edge of the area count with the area share of their grid cell. In the report "Spatial resolution"
Cell grid (assessment) 0.5° × 0.5° (azimuth × elevation), fixed
Capture margin of the hit check half the cell diagonal, 0.354°; for narrow lobes (smallest semi-axis < 1.5°, largest < 6°) half the diagonal of the point grid
Display grid 0.5°, 0.25° or 0.125° per PV area; display only
Back side / grazing view no reflection when seen from behind; for ground-mounted and racked areas already at more than 89° between viewing direction and module normal; for trackers per time step and calculation point
Cell rules blocked if more than half of the points are; outside the field of view if all points are outside; shaded according to the ray from the cell centroid and, with terrain occlusion, the nearest sampling point
Obstacle silhouette 0.05° azimuth per step, per observation point
Terrain occlusion near horizon per observation point, 2 m grid, 0.5° azimuth, steps of 0.05°, range up to 10 km; shading of the PV areas at sampling points in a 25 m grid (coarser for large installations, at most about 600) at the height of the module top edge, range 2 km, sampling with the grid spacing, further out 1 % of the distance; if switched on
Horizon lines (far-field shading) PVGIS, 48 directions, per PV area at the centre of the corner points; if activated
Trackers tracking angle per time step (pvlib), backtracking with GCR, rest angle during backtracking; all tracking parameters required, no substitute values
Elevation data source chain of the project (Ch. 6); the report lists the sources used

The app sends the values for temporal resolution, solar diameter and the upper limit of the point grid as fixed values with every simulation start; they cannot be changed. The report documents the parameters used in the chapter "Simulation Parameters" (Ch. 14).